Evaluating the Spectral Acceleration Amplification Effects on the Seismic Response of Elevated Steel Water Tanks

Document Type : Original Article

Authors

1 Earthquake Engineering Research Consultant, Yerevan, Armenia

2 Senior Structural Designer, E.S.S. Consulting Eng. Co., Tehran, Iran

Abstract

Water Tanks are amongst the most important structures which are used for storage and providing the water needed on the pick usage time in water supply networks.  The Seismic behaviour of such special structures is the main objective of current research, which was motivated by raising demands for design and construction of elevated water tanks. Hence, two structural models of steel elevated water tanks in Armneia, with capacities of 134m3 and 160m3, demonstrating a height of 24m and 30m respectively are selected as shown in Figure 1. Each model is considered to be empty, 50% and 100% full and is designed according to Armenian SNIP II-6.02 seismic code for all filling strategies, taking into account the spectral acceleration level equal to Sa=0.40g. On each model, the information of Convective mass, Impulsive mass and the spring stiffness of the convective and impulsive masses are added, due to the Housner’s Equivalent Mass-Spring theory, considering Soil-Structure Interaction (SSI) effects at the meantime. Earthquake Analysis procedures of the whole fluid-tank systems are completed by the means of Time History Analysis method, using 3 horizontal components of selected accelerograms, recorded on soil categories of Rock, Dense Soil and Loose Soil respectively, scaled to spectral acceleration levels of Sa=0.2g ~1.0g. Finally, the seismic response is computed for the filling strategy of Empty, 50% full and 100% full conditions for both models.

Keywords


[1]-Chopra, A. K., 2012, Dynamics of Structures:Theory and applications to Earthquake Engineering (4thed.), Prentice Hall,Englewood Cliffs.
[2]-Dogangun, A., Ayvaz, Y. and Durmus, A., 1997, Earthquake Analysis of Water Tanks, 4th International Conference on Civil Engineering, 1, Sharif University of Technology, 400-409
[3]-Haroun, A. H. and Temraz, M. K., 1992, Effects of Soil-Structure Interaction on Seismic Response of Elevated Tanks, Soil Dynamics and Earthquake Engineering, 11, 73 – 86.
[4]- Housner, G. W., 1963, Dynamic Behavior of Water Tanks, Bulletin of the Seismological Society of America, 53, 381-387.
[5]-SNIP II-6.02, 2006, Armenian Code of Practice for Seismic Resistant Design of Buildings, Report No.24 of Ministry of Urban Planning, Yerevan, Republic of Armenia.
[6]-Wilson, E. L., and Khalvati, M., 1983, Finite element for the dynamic analysis of fluid-solid system, International Journal, 19, 5-15.